PRODUCT
FEATURES |
REQUIRED FOR
SAFE WORKING /
BATTERY
PROTECTION |
THREE SIXTY
CFL UPS |
BENEFITS FOR
THREE SIXTY CFL
UPS CUSTOMERS |
OTHERS |
DISADVANTAGES
IN OTHERS |
Circuit design |
Should be SMPS
based for operation
on wide range of
mains voltage |
SMPS based
wide range
with defined
limit |
Safe working of
CFLs
and long
product life |
Narrow range or
unlimited wide range |
Can damage
components and
CFLs |
Mains Low
Voltage Cut-off |
Should switch
over to
back up mode
if
mains voltage goes
below 90 Volts |
Switches to back up
mode at 90 Volts |
No danger of damage to
CFLs/mobile chargers
and will always provide
back up light in
low voltage areas |
No switch over to
back up mode even
if voltage is lesser
than 90 Volts |
CFL will not glow
and there will be no
back up light in low
voltage areas |
Mains High
Voltage Cut-off |
Should cut off mains
supply if voltage is
above 320 Volts |
Cuts mains supply
above 320 Volts |
No danger of damage
to CFLs/mobile chargers
connected |
In some products
Mains is not cut off
even if mains voltage
is above 320 Volts |
CFLs and mobile
chargers connected
will be damaged |
Battery charging
current |
Should be around
0.7 Amp to 0 .8 Amp |
0.8 Amp |
Longer battery life |
It varies from
0.5 Amp to 1.0 Amp
in different models |
If it is less than
0.7 Amp battery
will not charge properly
and if it is more than
0.8 Amp then battery
will be damaged |
Battery voltage
lower cut off limit
during back up |
System should turn off
if battery voltage
drops below 10.2 volts |
10.2 Volts |
Battery is no deep
discharged and
prevented from damage |
7 Volts |
Battery will be
deep discharged and
will be damaged |
Battery voltage
higher cut off limit
during charging |
Should be 14.4 V |
14.4 Volts |
Battery is not over
charged and prevented
from bulging/bursting |
Over 14.4 Volts |
Battery will be
damaged due to
overchage |