TECHNICAL SPECIFICATIONS - DIGITAL HOME UPS
Rating 650VA 850VA 1450VA
Model No. Arrow 650 Arrow 850 Arrow 1450
MAINS MODE
Home Range
100 - 290V±10V AC
UPS Range
180 - 260V±10V AC
BATTERY
Battery Recommended
100AH-200AH / 12V
No. of Batteries 1 1 2
CHARGING
Charging Voltage (Boost) 14.30 ± 0.2V 28.60 ± 0.1V
Charging Voltage (Float) 13.60 ± 0.2V 27.20 ± 0.1V
Normal Charging Current 10.0 ± 1.0Amp
High Charging Current 12.0 ± 1.0Amp
INVERTER MODE
Output Voltage 200 - 270 ± 5V
Wave Form Quasi Sinewave
Frequency 50 ± 0.5Hz
Over Load 110% Load
Over Load Reset 4 Times before Shutdown
Short Circuit Protection H-UPS Shut down
Invertor Shutdown (Battery Low Position) 10.20 ± 0.2Vdc 20.40 ± 0.2Vdc
AUDIO / VISUAL INDICATIONS
MAINS ON LED 1 :CONTINUES ON
UPS ON LED 2 : CONTINUES ON
BATT. CHARGING / CHARGED LED 3 : BLINK / OFF
LOW BATTERY LED 4 : CONTINUES ON WITH BEEP
OVERLOAD LED 5 : CONTINUES ON WITH BEEP

Subject to VA Rating technical specification of the appliances.